Water and air ozone treatment as an alternative sanitizing technology [abstract]

Auteurs-es

  • Mauro Martinelli Ospedale San Pietro FbF, Rome.
  • Francesca Giovannangeli Ospedale San Pietro FbF, Rome.
  • Sara Rotunno Ospedale San Pietro FbF, Rome.
  • Claudia Maria Trombetta University of Siena
  • Emanuele Montomoli University of Siena

DOI :

https://doi.org/10.7203/jo3t.3.4.2019.15426

Mots-clés :

water sanitization, ozone

Résumé

PURPOSE: Investigate the effectiveness of ozone treatment as an alternative sanitizing technology to conventional disinfectants in reducing the microbial contamination of both water and air. METHODS: Ozone was added for 20 minutes to a well-defined volume of water and air by the system named “Ozonomatic®”. The effectiveness of ozonation was determined by counting CFU/m3 or mL of bacteria present in samples of air or water collected before (T0) and after (T1) the addition of ozone and comparing the microbial load of different bacteria present in ozonized and non-ozonized samples. RESULTS: When the ozonation equipment was located at 30 cm from the surface of the water in the bath tub in which the bacteria were inoculated, the treatment was able to reduce the microbial load present in the aerosol by 70.4% at a temperature of 36°C for 48 hours. Conversely, at 22°C for 5 days, only a modest decrease (9.1%) was observed. Escherichia coli and Pseudomonas aeruginosa were completely eliminated. A 93.9% reduction was observed for Staphylococcus aureus, followed by Streptococcus faecalis (25.9%). The addition of ozone to water was able to almost eliminate Staphylococcus aureus (98.9% reduction) and also to exert a strong impact on Legionella pneumophila (87.5% reduction). Streptococcus faecalis and Pseudomonas aeruginosa showed a decrease of 64.2% and 57.4%, respectively. Conversely, only a 26.4% reduction was observed for the bacterium Escherichia coli. This study showed that the addition of ozone in the air exerted a modest reduction on microbial load at 36°C, whereas no effect was observed at 22°C. CONCLUSIONS: Aqueous and gaseous ozone treatments were effective against microbial contaminants, reducing the CFU of the microorganisms and confirming its efficacy in water and air disinfection.

Téléchargements

Les données relatives au téléchargement ne sont pas encore disponibles.

Bibliographies de l'auteur-e

Mauro Martinelli, Ospedale San Pietro FbF, Rome.

Department of Internal Medicine

Francesca Giovannangeli, Ospedale San Pietro FbF, Rome.

Department of Internal Medicine

Sara Rotunno, Ospedale San Pietro FbF, Rome.

Department of Internal Medicine

Claudia Maria Trombetta, University of Siena

Department of Molecular and Developmental Medicine

Emanuele Montomoli, University of Siena

Department of Molecular and Developmental Medicine

Téléchargements

Publié-e

2019-12-19

Comment citer

Martinelli, M., Giovannangeli, F., Rotunno, S., Trombetta, C. M., & Montomoli, E. (2019). Water and air ozone treatment as an alternative sanitizing technology [abstract]. Journal of Ozone Therapy, 3(4), 23. https://doi.org/10.7203/jo3t.3.4.2019.15426
Metrics
Views/Downloads
  • Résumé
    947
  • PDF
    473